Current Position:   HOME > Products
Product

Product name:

08 Fast Connector

Product description

SC Connector(SC/UPC &SC/APC)

1.Description:

Fast Field Assembly Optical Connector is designed to manage on-site fiber connections with ease of maintenance for installers. It does not require additional practices or adhesives. It reduces connection defect rate by allowing re-assembling several times in the field.  

2.Features:

  • Fast and easy on-site installation with stability
  • Eliminated field polishing
  • No adhesives or electrical power required
  • Reduced connection defect rate by re-assembling
  • Compatible with 3x2mm.

3. Application:

  • Premise environments
  • Connections at the desk for LAN environments
  • Patch panels
  • Fiber to the Subscriber( FTTx ) applications
  • Equipment test leads         

4. Structure and Dimension of the SC Ferrule (It’s in accordance to IEC61754-4(2002-03) Ed.1.2.

                           UPC Ferrule

 

                              APC Ferrule

5.Ferrule Specifications:

No

Parameter

Specification

1

Ferrule Type

Fully Zirconia-Ceramic

2

Nominal ferrule diameter for SC connector

2.5mm+0.5um

3

Fiber Concentricity

1um

 

The ferrule end-face geometry comply with Telcordia GR-326 specifications and is measured based on an optical interferometric measuring technique.

 

6.Physical Specifications:

Item

Size(mm)

Insertion Loss

Return Loss

SS-SC/PC

53.5 x 9 x 7.3

≤0.3dB

≥50dB

SS-SC/APC

53.5 x 9 x 7.3

≤0.3dB

≥55dB

 

7. Technical Specifications

Category

Condition

Test Standards

Insertion loss

-

≤0.3dB

Return loss

-

SC/UPC: ≥50dB, SC/APC: ≥55dB

Vibration

Frequency range: 10-55-10Hz

Amplitude: 1.52mm(±0.75mm)

Cycle: 4 minutes

Time: 1 hour / X.Y.Z direction

 

Insertion loss variation: ≤0.3dB

 

Tension

more than 5 kg for cable jacket

Insertion loss variation: ≤0.3dB

Impact

Free fall: 4 M

Insertion loss variation: ≤0.3dB

Repeat-connection with adaptor

500 times

Insertion loss variation: ≤0.3dB

Temperature Cycle

Cycle: 8 hours

Total: 12 cycles / 96 hours

Temperature Maintenance: 1 hour

*Cycle: 23 → -40 → 23 → +75 → 23

Insertion loss variation: ≤0.3dB  (before, after and during the test)

Return loss: ≥35dB (during the test)

No Mechanical damage (including transform, damage)

 

Temperature /  Humidity Deterioration

 

40 ℃ (relative humidity : 95%)

   Time: 96 hours

Insertion loss variation: ≤0.3dB   (before, after and during the test)

Return loss: ≥40dB  (during the test)

No Mechanical damage (including transform, damage)

8.Standard Package

#

Model

Components

1

FAOC-SC/PC

FAOC unit, Installation Guide

2

FAOC -SC/APC

FAOC unit, Installation Guide

Measurement Jig is provided for every 50 connectors.

Submit
Submitted successfully! x

We will call you back soon!

OK